WSJT-X has to be set up to use the same RTS keying and the the /dev/ttyUSB1 
port.

Just tested it here and it uses it correctly (though I tested on Windows).
Mike W9MDB




 

    On Thursday, June 23, 2022 at 03:53:35 AM CDT, Hrafnkell Eiriksson via 
wsjt-devel <wsjt-devel@lists.sourceforge.net> wrote:  
 
 > Why do you have rst_state=ON?  That conflicts with ptt-type=RTS and might be 
 >why it's not working.I have rts_state and dts_state ON to power the CAT 
 >cable. The --set_conf option only seems to apply to the rig-file device, not 
 >the ptt device. I can remove the rts_state=ON, it has no effect on PTT
PTT over hamlib is working, it's just WSJT-X that is not using it. I can use 
e.g. a voice keyer in Log4OM and it does PTT properly through hamlib.
73 de Hrafnkell TF3HR
On Wed, Jun 22, 2022 at 11:07 PM Black Michael via wsjt-devel 
<wsjt-devel@lists.sourceforge.net> wrote:

The 706MKIIG does not do CAT PTT per se but the ptt-type=RTS should work.
Why do you have rst_state=ON?  That conflicts with ptt-type=RTS and might be 
why it's not working.
And dtr_state=ON would only be needed if your CAT cable needs power from the 
computer to work.
Mike W9MDB

 

    On Wednesday, June 22, 2022 at 11:35:27 AM CDT, Hrafnkell Eiriksson via 
wsjt-devel <wsjt-devel@lists.sourceforge.net> wrote:  
 
 Hi
I'm running WSJT-X v2.5.4 on a Win10 computer.I've set up hamlib rigctld 
(version 4.4) on a Raspberry Pi and connected it to my Icom706mk2g.I'm using 
two com ports from the RPi, one for CAT control and one for PTT.I've set  
WSJT-X  to use hamlib for rig control and pointed it to the ip:port of my RPi.
Test CAT works fine and  WSJT-X can set and read the frequency if I have PTT 
method set to Vox.If I set PTT method to CAT then Test CAT fails with the 
error:Rig failureHamlib error: IO errornetwork.c(441):network_close 
return(0)iofunc.c(361):port_close return(0)rig.c(1047):rig_open return(-6) IO 
errornetwork.c(441):network_close return(0)iofunc.c(361):port_close 
return(0)iofunc.c(361):port_close return(0) while opening connection to rig

I can use the hamlib CAT PTT from other software such as Log4OM without 
issues.I would expect CAT PTT with hamlib rigcontrol in WSJT-X to behave the 
same, that is use hamlib calls to do PTT.
My rigctld command line isrigctld --model=3011 --rig-file=/dev/ttyUSB0 
--serial-speed=4800 --port=4532 
--set-conf=stop_bits=1,dtr_state=ON,rts_state=ON --ptt-file=/dev/ttyUSB1  
--ptt-type=RTS -Z
Am I setting something wrong or misunderstanding something?
Thanks  Hrafnkell TF3HR_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel
  _______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel
  
_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to