bunglega wrote: > I think he means you have to have the DELL OpenManage software installed on > your DELL server. I've had some success monitoring my DELL hardware (more > than my SUN hardware actually). I am still unable to populate the CPU info > ... searching the forums will yield threads where people have the same > problem but from what I have found - no one knows a solution or the solution > provided does not fix the problem. > > With regards to the MIB question - I would like an answer to this as well? I > have imported the MIBS, now how can I add that information to the devices > details page? Power Supplies, DRAC, PERC controllers etc.
Same my problem, i fix'it reading file HPDevice.py and modify as my oid, whit this i'm able to import serial number, firmware version for my 3com switches, i think you hate to do the same , discover which OID you can use to get cputype, adjust in file DELLCpu.py , have you tryed with snmpget with oid in DELLCpuMap.py? ------------------------ Antonio Catani -------------------- m2f -------------------- Read this topic online here: http://community.zenoss.com/forums/viewtopic.php?p=11790#11790 -------------------- m2f -------------------- _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users