Hi All, Please see below for two staff scientist positions available at our
Cryo EM core facility at NYU. Feel free to email me directly with questions!
Thanks, Gira
———
Cryo EM Staff Scientist positions at NYU
Location: Manhattan, New York
To apply: Please
Thank you all for the input. I think my problem got solved.
The structure was determined by cryo-EM at 3.2 A. I used
phenix.real_space_refine to refine the structure using the model with no
hydrogen. the statistic report directly from phenix was pretty good but not
from pdb validation server
Dear Wolfram,
the principles of data integration do not differ much between small molecule and
macromolecular data (XDS, DIALS, HKL2000, mosflm, and SAINT can be used for
either), hence the advantages reported for chemical crystallography should apply
likewise for macromolecular crystals.
In
Dear Xiaodi
The wwPDB validation service does indeed add hydrogens using Reduce before
calculating clashes.
For more details of what processes are run when generating the wwPDB validation
report see the on-line help
ReNaFoBiS. Oleron 2019. Registration is now open
We are pleased to announce the 6th RéNaFoBiS Oléron workshop, dedicated to
Integrative Structural Biology, that will take place on the Oléron island
(France), from June the 21th until June the 28th, 2019. The main objective of
this workshop is
Applications are invited for a PhD position, starting any time in 2019,
in the group Prof. Michael Hothorn at University of Geneva
(http://structplantbio.org). The lab combines structural biology (X-ray
protein crystallography, cryo electron microscopy) and quantitative
biochemistry with
First announcement
HANDS 2019
HFIR/SNS Advanced Neutron Diffraction and Scattering Workshop
Oak Ridge, TN. June 19 - June 14, 2018
Oak Ridge National Laboratory, in conjunction with North Carolina State
University, and support from the National Science Foundation and the Shull
Wollan Center -
Wow, that’s pretty impressive. I hadn’t realized the high levels of DQE you had
achieved. If you could make one for visible photons, you’d make a lot of
microscopists really happy.
I also had not realized that QE of other detectors is intensity dependent—seems
counter-intuitive.
JPK
Applications are invited for a PhD studentship starting from September 2019 in
Dr. Arianna Fornili’s group at Queen Mary University of London and in
collaboration with Dr. Julien Ochala at King’s College London.
The aim of the project is to design and test small molecules that can either
Doesn’t the phrase “each-and-every single photon counting capability” imply
that quantum efficiency is 100%? I don’t think this is possible—what is the
quantum efficiency of these detectors?
JPK
+
Jacob Pearson Keller
Research Scientist / Looger
Dear All,
The British Crystallographic Association (BCA) Spring Meeting is taking place
this year at the University f Nottingham from Monday 15th April to Thursday
18th April, 2019. With a range of sessions highlighting integrated approaches
to structural biology and the latest developments in
Dear Wolfram,
For the past several years, Rigaku has been installing only HPC (Hybrid Photon
Counting) X-ray area detector -based diffractometer systems: in conjunction
with microfocus rotating anode, microfocus sealed-tube and other X-ray sources.
(Most recently, we have been deploying
12 matches