Re: CAMLST LOCATE and SCRATCH

2011-08-14 Thread Richard L Peurifoy
On 8/11/2011 2:08 PM, DanD wrote: Scott, To handle SMS you need to SCRATCH first then UNCAT (can't have uncataloged SMS data sets). Or you can invoke IDCAMS to do the DELETE and do it all at once. Actually if you issue a scratch SVC specifying an SMS volume, it will look up the data set in

Re: CAMLST LOCATE and SCRATCH

2011-08-11 Thread Binyamin Dissen
As the failing PSW is problem state, and the abend location is off of R15, I would expect that the SCRATCHD routine (which is not included) is at fault for the abend. Of course the scratch failed, but that is the cause your routine was driven. On Wed, 10 Aug 2011 16:50:32 -0700 Scott Ford

Re: CAMLST LOCATE and SCRATCH

2011-08-11 Thread Scott Ford
to everyone else Regards,  Scott J Ford Software Engineer http://www.identityforge.com   From: Gerhard Postpischil gerh...@valley.net To: IBM-MAIN@bama.ua.edu Sent: Wednesday, August 10, 2011 10:48 PM Subject: Re: CAMLST LOCATE and SCRATCH On 8/10/2011 7:50 PM, Scott Ford wrote: I need a little

Re: CAMLST LOCATE and SCRATCH

2011-08-11 Thread Shmuel Metz (Seymour J.)
In 1313020232.153.yahoomail...@web65509.mail.ac4.yahoo.com, on 08/10/2011 at 04:50 PM, Scott Ford scott_j_f...@yahoo.com said: My question is this...after a LOCATE finds the dataset ..Is it correct that the dataset name has to be moved into the DSNSCR variable name Normal practice would be to

Re: CAMLST LOCATE and SCRATCH

2011-08-11 Thread Scott Ford
appreciated. My problem is i am getting olderas everyone is ...61 in 9 days lol Scott J Ford Software Engineer http://www.identityforge.com   From: Shmuel Metz (Seymour J.) shmuel+ibm-m...@patriot.net To: IBM-MAIN@bama.ua.edu Sent: Thursday, August 11, 2011 9:36 AM Subject: Re: CAMLST LOCATE

Re: CAMLST LOCATE and SCRATCH

2011-08-11 Thread DanD
Subject: Re: CAMLST LOCATE and SCRATCH Gerhard, Absolutely right, found the S0C1 but had two other issues .. 1. Must issue a CAMLST uncatalog request for dataset name first 2. Camlst scratch needs the correct parameter list After doing 1 and 2 it worked like a champ. Thanks for the help and I have

Re: CAMLST LOCATE and SCRATCH

2011-08-11 Thread Scott Ford
Thanks much appreciated because I dont know SMS that well Scott J Ford Software Engineer http://www.identityforge.com   From: DanD mvs-j...@sympatico.ca To: IBM-MAIN@bama.ua.edu Sent: Thursday, August 11, 2011 2:56 PM Subject: Re: CAMLST LOCATE and SCRATCH Scott, To handle SMS you need

CAMLST LOCATE and SCRATCH

2011-08-10 Thread Scott Ford
All:   I need a little help, maybe a lot of help. I wrote an Assembler routine that is able to locate a dataset non-racf, non-sms and the routine finds it fine , no problem. When I go to CAMLST SCRATCH it i have a S0C1 it looks like in dfp...So here is my snippet of my source showing LOCATE and

Re: CAMLST LOCATE and SCRATCH

2011-08-10 Thread Gerhard Postpischil
On 8/10/2011 7:50 PM, Scott Ford wrote: I need a little help, maybe a lot of help. I wrote an Assembler routine that is able to locate a dataset non-racf, non-sms and the routine finds it fine , no problem. When I go to CAMLST SCRATCH it i have a S0C1 it looks like in dfp...So here is

Re: CAMLST LOCATE and SCRATCH

2011-08-10 Thread Mike Schwab
On Wed, Aug 10, 2011 at 6:50 PM, Scott Ford scott_j_f...@yahoo.com wrote: deleted 19.25.29 JOB00166  IGD17040I ERROR IN DADSM PROCESSING FOR DATA SET  570    570 SFORD.TEST1    570 HISTORIC RETURN CODE IS 4 DIAGNOSTIC INFORMATION IS 04280039 19.25.29 JOB00166  IGD306I