It's a brand new product. They used to make a really good outdoor patch cables that were US Stocked about 2 years ago. I have several of them deployed, but then they stopped making them. It sounds like for these, they are all custom made, so no stock.

On 3/31/2020 10:12 AM, Josh Baird wrote:
I didn't realize they were making "FTTA" patch cables now. I have used the outdoor armored patch cables from FS in the past. I'll check these out.. wish they stocked them in the US.

On Tue, Mar 31, 2020 at 11:08 AM Nate Burke <n...@blastcomm.com <mailto:n...@blastcomm.com>> wrote:

    What is the ballpark?  $1/ft?  $5/ft?

    Does the outdoor jacket come all the way to the LC Connector?

    My order from Feburary of these
    https://www.fs.com/products/97938.html is finally getting
    delivered tomorrow.  I'm interested to see if the picture is
    accurate.

    On 3/31/2020 10:03 AM, dave wrote:
    Best-tronics and its priced per foot
     It doesnt have the boot like cambium but I do believe they are
    making it.
    Call for pricing.


    On 3/30/20 8:06 PM, Nate Burke wrote:
    Where are you getting the Tatical SM fiber from?  Pricing?

    On 3/30/2020 5:22 PM, dave via AF wrote:
    That may work for most radios limited by 4 possibly 6 450i or
    something equivalent.
     If running medusa 3.65 and 5.7 radios youll need #8 min by 2
    pair pvc jacket or better for outdoor operation.
    We have a few like this and learned the hard way even with #10
    hybrid cable that would not fly due to the loss in the wire at
    250'
    We use Tactical SM fiber LC-LC pre-terminated
    We also use Duracomms
    
https://duracomm.com/product-category/rack-mount-power-supplies/centri-series-he1u-mu/
    Note we use the 50Amp version of this.
    Youll need most of it to get to the top to sustain that 48vDC
    those beast need lol.
    We now have our 3rd site up with Fiber going to everything and
    #8 stranded pairs up the tower for power.
    Also, be sure and add in the surge stuff.


    On 3/30/20 4:46 PM, TJ Trout wrote:
    I've been thinking of offering hybrid fiber / 12 awg copper
    pre-terminated cables... if anyone has a desire for such a
    thing, let me know the fiber count, connector type and lengths
    you would want...

    On Mon, Mar 30, 2020 at 2:35 PM Matt
    <matt.mailingli...@gmail.com
    <mailto:matt.mailingli...@gmail.com>> wrote:

        What is everyone using for fiber up tower? What using for
        connectors?

-- AF mailing list
        AF@af.afmug.com <mailto:AF@af.afmug.com>
        http://af.afmug.com/mailman/listinfo/af_af.afmug.com











-- AF mailing list
    AF@af.afmug.com <mailto:AF@af.afmug.com>
    http://af.afmug.com/mailman/listinfo/af_af.afmug.com




-- 
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to