Mpls TE using Telco Systems

Gino A. Villarini
@gvillarini



On Apr 14, 2015, at 6:25 PM, Sam Lambie 
<[email protected]<mailto:[email protected]>> wrote:

We currently have a Dragonwave Dual Mounted 2+0 PTP setup that is Ether 
channeled with Cisco switches. Currently each radio link is at 300 mbps. Easy 
to Ether channel as they are the same sized pipe. Once you get into links of 
differing throughput, then Ether Channel will fill up to the smallest pipe and 
the rest is wasted.
In the the next month, we are going to install another 2+0 link in the same 
direction that should have up to 1.2 gb aggregate on that link alone. And 600 
mbps on the DW link. So my question is how to essentially bond both links of 
differing sizes without wasting wireless throughput. Is there something better 
than Ether channel?




--
--
Sam Lambie
Taosnet Wireless Tech.
575-758-7598 Office
www.Taosnet.com<http://www.newmex.com>