Saji,
We use TEC (Tivoli Enterprice Console)- Migrating to Netcool/Ominbus as the
correlation application for all events whether node_down(server), monitoring
process/filesystem on server, databases, 4D-jobs, monitoring the network,
etc. TEC is integrated with a extensive script (in-house), which populate
runmacro - and generate tickets. Omnibus has a remedy gateway, that tickets
are managed from within the tool/gui, you can send to Remedy automatically
based configuration. The gateway is bi-directional/uni-directional.
runmacro --
Usage: runmacro [-h <homeDir>] [-d <macroDir>] [{-x <server>} ...] { -e |
-i }
macroName [-p param=value ...] [-U <user>] [-P <password>]
[{-w | -W } domainName] [-a portNum] [-O]
OR
runmacro -o <output filename> [{-x <server>} ...] -U <user>
[-P <password>] [{ -f | -s } <form>] [-t {arx|csv|xml}]
[-n]
[{-w | -W } domainName] [-a portNum] [-O] [-Q
internalqualformat] [-q clienttoolqualformat]
[-Z <internalformatqualification
filename>] [-z <clientformatqualification filename>]
--
View this message in context:
http://ars-action-request-system.1093659.n2.nabble.com/Creating-Trouble-tickets-automatically-tp6351848p6352000.html
Sent from the ARS (Action Request System) mailing list archive at Nabble.com.
_______________________________________________________________________________
UNSUBSCRIBE or access ARSlist Archives at www.arslist.org
attend wwrug11 www.wwrug.com ARSList: "Where the Answers Are"