At 2/21/2012 05:32 PM, John Ehrman wrote:
Dave, your memory is too good.  ASMA033W (in HLASM R2) was changed to
ASMA033I (in HLASM R3), at which time two additional alignment messages
were added (212 and 213).

I hope this will help:

ASMA212W and ASMA213W are controlled by the FLAG(ALIGN) option.
These messages are issued even if the NOALIGN option is used
(assuming FLAG(ALIGN) is still active) - whereas ASMA033I is
suppressed if NOALIGN is specified.



Why would anyone specify the NOALIGN option?

I don't know, John... But that's not my issue.

My issue is that the ASMA033I variant flags issues in my code that I
want to eliminate, but because ASMA033I leaves RC=0, I have no quick
and easy way to notice them without manually checking all 195
separate assemblies!

So I want an option (call it "HARDALIGN" or whatever) whereby
ASMA033I conditions will be reported as ASMA033W conditions and will
set at least RC=4.

Can that be done?



Dave Cole              REPLY TO: [email protected]
ColeSoft Marketing     WEB PAGE: http://www.colesoft.com
736 Fox Hollow Road    VOICE:    540-456-8536
Afton, VA 22920        FAX:      540-456-6658