Archimago wrote: 
> Unfortunately it's more complicated. They're not live at the same time,
> you have to select the Digital Output for EDO and the USB device
> presents as a separate option which reboot the Touch each time the
> selection is changed (ie. USB vs. SPDIF's).
> 
> I tried looking into this this AM with my Essence One plugged in to the
> Touch's USB. Unfortunately there's some really strange incompatibility.
> EDO is aware of the E1's sampling rates up to 192kHz as an asynch device
> but when I play tracks it cannot match the sampling rates up
> appropriately!  It insists on playing 16/44 as 96kHz, 24/44 & 24/96 as
> 192kHz, and 24/192 as 44kHz!  As such, I can't get any measurements at
> all since nothing matches. How bizarre...
> 
> I'll post this finding up on the EDO thread and see if anyone has a
> suggestion.

Thanks for the info.  I was referring to the earlier comment and
something much simpler in terms of the question of testing S/PDIF vs
Toslink (no USB involved).  And this could be done without EDO being
involved.


------------------------------------------------------------------------