Hi Ira - the relief valve popping is on the steam boiler

On Friday, April 24, 2015 at 2:09:12 PM UTC-4, Ira wrote:
>
>  Hello StevieG.,
>
> Friday, April 24, 2015, 11:00:19 AM, you wrote:
>
>  
>  After cleaning the screen etc, and pulling two shots, the pressure valve 
> popped again and kept venting.   Both front guages were 2+ bar.
>   
>
> Which boiler, steam or brew?
>
> Steam boiler means you need a new pressurestat. Brew boiler is harder.
>
> -- Ira
>

-- 