Most of us have switched to the Jaeger pressurestat. Chris Coffee has them
and they work great.
Herman

On Wed, Dec 23, 2015 at 1:32 PM, Curtis H <[email protected]> wrote:

> I have a Brewtus 2 with a PID purchased used just over a year ago.  I'm
> having periodic problems with the steam boiler overheating and the
> overpressure valve releasing steam.  I don't trust leaving the house with
> it on anymore...
> I'm wondering if anyone has swapped out their Mater pressurestat for a
> Sirai.  I'm looking at the smaller 2-pole that's used on a Rocket
> (P203T01).  It definitely fits.  My question is with the wires:  On the
> Mater there's one wire to each of NO (Normally Open), NC (Normally Closed)
> and Common.  On the Sirai, there's NC and Common.  What do I do with the
> Normally Open wire?
>
> Curtis
>
> --
> You received this message because you are subscribed to the Google Groups
> "Brewtus" group.
> To unsubscribe from this group and stop receiving emails from it, send an
> email to [email protected].
> To post to this group, send email to [email protected].
> Visit this group at https://groups.google.com/group/brewtus.
> For more options, visit https://groups.google.com/d/optout.
>

-- 
You received this message because you are subscribed to the Google Groups 
"Brewtus" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send email to [email protected].
Visit this group at https://groups.google.com/group/brewtus.
For more options, visit https://groups.google.com/d/optout.

Reply via email to