On Tue, 17 Jun 2008, Richard A Steenbergen wrote:
On Tue, Jun 17, 2008 at 11:27:23PM +0200, Peter Rathlev wrote:
Changing switching mode power cycles the modules by the way. I guess
that's a gotcha. :-)
I'm pretty sure thats not true. You may be thinking of PFC/DFC modes,
where inserting a "lower" capability card (3a or 3b into a 3bxl system,
etc) brings down the entire switch to the lowest common card, and requires
a reboot of the entire system to bring it back (after removing the
offending card of course). This doesn't happen to the switching mode at
all.
I think Peter had http://www.cisco.com/en/US/ts/fn/610/fn61935.html in
mind.
thanks,
andrew