I believe that is correct. When a switching mode changes automatically due to cards with different capabilities being inserted, then there is no chassis or card resets. However, when you force bus mode the effected cards are reset.
Fred Reimer, CISSP, CCNP, CQS-VPN, CQS-ISS Senior Network Engineer Coleman Technologies, Inc. 954-298-1697 -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Andrew Yourtchenko Sent: Wednesday, June 18, 2008 7:55 AM To: Richard A Steenbergen Cc: Pham, Loc; Cisco NSPs Subject: Re: [c-nsp] fabric switching enable On Tue, 17 Jun 2008, Richard A Steenbergen wrote: > On Tue, Jun 17, 2008 at 11:27:23PM +0200, Peter Rathlev wrote: >> Changing switching mode power cycles the modules by the way. I guess >> that's a gotcha. :-) > > I'm pretty sure thats not true. You may be thinking of PFC/DFC modes, > where inserting a "lower" capability card (3a or 3b into a 3bxl system, > etc) brings down the entire switch to the lowest common card, and requires > a reboot of the entire system to bring it back (after removing the > offending card of course). This doesn't happen to the switching mode at > all. I think Peter had http://www.cisco.com/en/US/ts/fn/610/fn61935.html in mind. thanks, andrew _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/