On 9/24/2010 4:07 PM, Jay Nakamura wrote:
> Unless you have fancy DS3 test set, only way to find out is start
> using it.  We saw bunch of errors but telco swore up and down that
> line was clear.  This list clued me into possible hot circuit.  Stuck
> a attenuator in the Rx side and error disappeared.

Our old DS3 came with the coax-to-RJ45 balun adapters.  Rather than attenuate, 
we stuck
a long Cat5 jumper in the middle, worked just as well.  This on a 7200VXR.

Jeff