Hi,

On Fri, Jan 20, 2012 at 07:29:26PM -0500, Jon Lewis wrote:
> We do this with single supervisors, and a full redundant identically 
> configured chassis.  Customer's who care get a link to each chassis.

Same here.  Not that much hardware outage over the last years (one 
Sup720-10G arrived DOA, one Sup32 went bad, two or three 61xx line 
cards) - but there's IOS upgrades, and sometimes bad IOS versions, 
so having separate chassis for redundancy (with different IOS versions)
is very useful.

(... and this is reason #1 why we are not using VSS)

gert
-- 