Jackie-Jiang commented on code in PR #9642:
URL: https://github.com/apache/pinot/pull/9642#discussion_r1016616856
##########
pinot-segment-local/src/main/java/org/apache/pinot/segment/local/recordtransformer/DataTypeTransformer.java:
##########
@@ -92,6 +92,13 @@ public GenericRow transform(GenericRow record) {
// Single-value column
source = PinotDataType.getSingleValueType(value.getClass());
}
+
+ if (source == PinotDataType.BYTES && dest == PinotDataType.STRING &&
value instanceof byte[]) {
Review Comment:
This will introduce more severe backward compatibility issue, where the
bytes values are expected to be converted using hex encoding. Let's not try to
handle this
--