sajjad-moradi commented on code in PR #9642:
URL: https://github.com/apache/pinot/pull/9642#discussion_r1017193744


##########
pinot-segment-local/src/main/java/org/apache/pinot/segment/local/recordtransformer/DataTypeTransformer.java:
##########
@@ -92,6 +92,13 @@ public GenericRow transform(GenericRow record) {
           // Single-value column
           source = PinotDataType.getSingleValueType(value.getClass());
         }
+
+        if (source == PinotDataType.BYTES && dest == PinotDataType.STRING && 
value instanceof byte[]) {

Review Comment:
   In other words, the only way to use Fixed type in the input data is to have 
corresponding String column in pinot schema. With the provided bug fix, that 
behavior doesn't change for existing tables. For new tables, the correct way is 
to have pinot column as BYTES not STRING.



-- 
This is an automated message from the Apache Git Service.
To respond to the message, please log on to GitHub and use the
URL above to go to the specific comment.

To unsubscribe, e-mail: [email protected]

For queries about this service, please contact Infrastructure at:
[email protected]


---------------------------------------------------------------------
To unsubscribe, e-mail: [email protected]
For additional commands, e-mail: [email protected]

Reply via email to