Hi Yeoh, On Fri, Dec 2, 2011 at 7:31 PM, Yeoh Chun-Yeow <[email protected]> wrote: > Hi, Javier > > Can you advice the proper way to setup the multi-hop scenario if three of > the nodes are near to each others. I am using the "iw mesh0 mpath set xx > next_hop" for this. Is this enough?
We implemented two ways to force topologies for testing: blacklisting and whitelisting. For blacklisting you should set auto_plinks to true, wait for the fully connected topology to be created and then "prune" the links with plink_action block (all of this, with iw). For whitelisting you should set auto_plinks to false, flush all the established plinks, if any, and then manually establish peer links with plink_action open. If you don't care about what peer links are established but only would like to force a particular path, the set next_hop option should work. But IIRC, paths that are configured this way take precedence over dynamically established paths and never expire. So they will prevent your mesh network from self-healing. Cheers, Javier -- Javier Cardona cozybit Inc. http://www.cozybit.com _______________________________________________ Devel mailing list [email protected] http://open80211s.com/mailman/listinfo/devel