Hi Yeoh,

On Fri, Dec 2, 2011 at 7:31 PM, Yeoh Chun-Yeow <[email protected]> wrote:
> Hi, Javier
>
> Can you advice the proper way to setup the multi-hop scenario if three of
> the nodes are near to each others. I am using the "iw mesh0 mpath set xx
> next_hop" for this. Is this enough?

We implemented two ways to force topologies for testing: blacklisting
and whitelisting.
For blacklisting you should set auto_plinks to true, wait for the
fully connected topology to be created and then "prune" the links with
plink_action block (all of this, with iw).
For whitelisting you should set auto_plinks to false, flush all the
established plinks, if any, and then manually establish peer links
with plink_action open.

If you don't care about what peer links are established but only would
like to force a particular path, the set next_hop option should work.
But IIRC, paths that are configured this way take precedence over
dynamically established paths and never expire.  So they will prevent
your mesh network from self-healing.

Cheers,

Javier

-- 
Javier Cardona
cozybit Inc.
http://www.cozybit.com
_______________________________________________
Devel mailing list
[email protected]
http://open80211s.com/mailman/listinfo/devel