Logging on from work:

Garey, I thought about that last night and, as luck would have it, I had an 
extra good 6HS6, which I swapped.  There was no change.

The PTO seems to be a bit better with the cover removed, not the entire unit.  
Of course the frequency of the PTO changes considerably with the cover off.  
It's got me scratching my head, as there should really be no significant heat 
being generated in there...

W1ES

Date: Mon, 18 Jul 2011 10:11:15 -0400
From: Garey Barrell <[email protected]>
To: [email protected]
Subject: Re: [Drakelist] R-4A PTO, Act III
Message-ID: <[email protected]>
Content-Type: text/plain; charset=windows-1252; format=flowed

Steve -

This has been 'one of those' problems! Just a quick question.... I've forgotten 
if you said the PTO 
was stable outside the radio? IF so have you subbed the PreMixer tube? Possible 
load change on the 
PTO due to a tube anomaly?

73, Garey - K4OAH
Glen Allen, VA