Hi Chuck,

The router version I have is v.2.1.5 with WinKey v.10. The Keyer has power
and is working fine as either a standalone or with another logging program I
have been testing it with. After I configure DXBase and initialize the port
I get a message "Unable to open <K1EL CW> comport. This feature will be
turned off." Also, the micro Keyer stops working until I power the
keyer/interface down and restart it.

On the microHAM reflector there is mention that DXBase may have a problem
with the new version 10 of WinKey.

Please understand, I am not pointing a finger at anyone, I am just trying to
understand the problem. After all, the problem might be me and then I would
have to pull a foot out of my mouth. <grin>

If anyone, including the good folks at Scientific Solutions can shed light
on this mystery please jump in.

73,
Eric - VE3GSI.


-----Original Message-----
From: Chuck Guenther
Subject: [Dxbase] DXBase 2006 + WinKey via micro KEYER


Eric,

I'm using DXBase 2006 with the microHam keyer with the latest (V. 2.0)
router software and firmware upgrades.  I believe my keyer has the v. 9 K1EL
keyer chip in it.  Works great with the Omni 6 here for CW.   

I wonder if you have external power (13.8V) hooked up to your microKeyer?  

73,

Chuck  NI0C