Sandy,

As far as I know, there is no direct relationship between the strength of a
signal and receiver AGC.

My AD8307 power meter can measure signal strengths directly off an antenna
if called upon to do that, it goes down to -80 dBm (about S-8) with no other
amplification.  This is strictly a power meter, no AGC implied or
implemented - the output is the base 10 logarithm of the input signal.

All one must do is measure the strength of the received signal to drive an
S-meter - but it must be calibrated if it is used as an absolute measurement
device.

Yes, the implementation in most receivers derive the AGC voltage from the
same signal strength measurement circuits, so things get a bit mixed up, and
often appear as a 'chicken and egg' situation.

73,
Don W3FPR

> -----Original Message-----
>
> Circuitrywise, an "AGC/AVC free" S-meter is an oxymoron!  Can't have one
> without the other.
> (snip)
> 73,
> Sandy W5TVW
>
--