I remember many discussions on different CISPR Subcommittees on 
Swiss and Sweden's proposals and numerous papers presented on 
EMC Symposia in eighties and early nineties to replace OATS with 
absorbing clamp type measurements or to add clamp method as the 
alternative. All these proposals were rejected.

Keep in mind that correlation between two good, acceptable 'reference' 
OATS using the same measurement distance is not that great, could be 
as poor as 8 dB just due to a NSA deviation. How much more dB would 
be acceptable, that is the question.

I wish you and other EMC test method developers throughout the world 
good luck and success in developing acceptable alternative method to OATS. 

Mirko Matejic

---------
This message is coming from the emc-pstc discussion list.
To cancel your subscription, send mail to [email protected]
with the single line: "unsubscribe emc-pstc" (without the
quotes).  For help, send mail to [email protected],
[email protected], [email protected], or
[email protected] (the list administrators).