> > Geetha Balasubramanian <[email protected]> wrote (in >
<[email protected]>) about 'Radiated >
Emission Testing', on Tue, 22 Mar 2005:
>>
> > > There are 2 clock sources in the device, one runs at 12 MHz and the >
>other runs at 4 MHz. Frequencies showing up in the US lab report are >
>atleast the harmonics of these 2 frequencies. But frequencies mentioned >
>in the Taiwan lab report are looking funny (111.27, 135.3, 285.69 MHz.
> > >etc.)
> > John Woodgate wrote on 3/22/2005, 11:24 AM:
> > That does look odd. I wonder if they left the door open!
> Or the classic, cables through the room wall...
> Derek Walton
Or the equally humorous:
1. Where's my cellphone?
2. Where's the digital camera?
3. I forgot to torque the penetration port bolts!
4. So that's where the battery-powered DMM went to!
5. Uh oh, wrong coax cable.
And the list keeps growing.....
Ed
Ed Price
[email protected] WB6WSN
NARTE Certified EMC Engineer & Technician
Electromagnetic Compatibility Lab
Cubic Defense Applications
San Diego, CA USA
858-505-2780 (Voice)
858-505-1583 (Fax)
Military & Avionics EMC Is Our Specialty
---------------------------------------------------------------- This message
is from the IEEE Product Safety Engineering Society emc-pstc discussion list.
Website: http://www.ieee-pses.org/
To post a message to the list, send your e-mail to [email protected]
Instructions: http://listserv.ieee.org/listserv/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html
For help, send mail to the list administrators:
Scott Douglas [email protected] Mike Cantwell [email protected]
For policy questions, send mail to:
Richard Nute: [email protected] Jim Bacher: [email protected]
All emc-pstc postings are archived and searchable on the web at:
http://www.ieeecommunities.org/emc-pstc