> > Geetha Balasubramanian <[email protected]> wrote (in  >
<[email protected]>) about 'Radiated  >
Emission Testing', on Tue, 22 Mar 2005:

 >> 
> > > There are 2 clock sources in the device, one runs at 12 MHz and the  >
>other runs at 4 MHz. Frequencies showing up in the US lab report are  >
>atleast the harmonics of these 2 frequencies. But frequencies mentioned  >
>in the Taiwan lab report are looking funny (111.27, 135.3, 285.69 MHz.

> > >etc.) 


> > John Woodgate wrote on 3/22/2005, 11:24 AM: 
> > That does look odd. I wonder if they left the door open! 



> Or the classic, cables through the room wall... 

> Derek Walton 


Or the equally humorous: 

1. Where's my cellphone? 
2. Where's the digital camera? 
3. I forgot to torque the penetration port bolts! 
4. So that's where the battery-powered DMM went to! 
5. Uh oh, wrong coax cable. 

And the list keeps growing..... 

Ed 
Ed Price 
[email protected]     WB6WSN 
NARTE Certified EMC Engineer & Technician 
Electromagnetic Compatibility Lab 
Cubic Defense Applications 
San Diego, CA USA 
858-505-2780 (Voice) 
858-505-1583 (Fax) 
Military & Avionics EMC Is Our Specialty 

  

---------------------------------------------------------------- This message
is from the IEEE Product Safety Engineering Society emc-pstc discussion list.
Website: http://www.ieee-pses.org/ 

To post a message to the list, send your e-mail to [email protected] 


Instructions: http://listserv.ieee.org/listserv/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 


For help, send mail to the list administrators: 


Scott Douglas [email protected] Mike Cantwell [email protected] 


For policy questions, send mail to: 


Richard Nute: [email protected] Jim Bacher: [email protected] 


All emc-pstc postings are archived and searchable on the web at: 


http://www.ieeecommunities.org/emc-pstc


Reply via email to