"Stone, Richard" <[email protected]> wrote (in
<[email protected]>) about
'Radiated Emission Testing', on Tue, 22 Mar 2005:

>Is there a guidelins somewhere youve read about when to stop the normal
>spinning of the table and start the maximization of cables?

Not that I've read, but I don't run a test house. There may be a
guidance document used by members of the EMCTLA body in UK or even in
the European body.
--
Regards, John Woodgate, OOO - Own Opinions Only.
There are two sides to every question, except
'What is a Moebius strip?'
http://www.jmwa.demon.co.uk Also see http://www.isce.org.uk


This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/listserv/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas             [email protected]
     Mike Cantwell            [email protected]

For policy questions, send mail to:

     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to