In message <[email protected]>, dated Wed, 21 
Feb 2007, Bob Richards <[email protected]> writes:

>Once the product committee has determined what frequency range and test 
>level are to be used, and unless there is some provision in the product 
>standard for reducing the range or level, then Annex B or C of 
>61000-4-6 can't be used by anyone to modify the parameters set forth by 
>the product family standard. Am I correct in my interpretation?

Yes. Basic standards are subsidiary to Generic, Product Family and 
Product standards, in that order.

Of course, it may be that the product committee SHOULD have taken 
Annexes B and C into account and made provision in their standard 
accordingly.

Under the new EMC Directive, an appeal to either Annex, 'over the head' 
of the product family standard, is not ruled out, but full compliance 
with the product family standard cannot be claimed in that case. This is 
in accordance with the principle that the manufacturer must show 
compliance with the Essential Requirements, not with any particular 
standard. Showing compliance (full or in part) with a standard is simply 
means to that end.


-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
There are benefits from being irrational - just ask the square root of 2.
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

Reply via email to