I can live with that.

Chris Radek wrote:
> On Sun, Aug 05, 2007 at 09:06:44AM -0400, Dale wrote:
> 
>>No, if no axis words specified then G28 is invalid input and no axis 
>>should move.
> 
> 
> My understanding is a bare G28 is allowed in HAAS.  In Fanuc programs,
> since it's an error, nobody would write it, so its behavior in EMC
> doesn't matter.  In historical EMC, bare G28 was allowed and it still
> is, and gives the same behavior, so those programs don't break.
> 
> My thinking is that it's OK to give fewer errors than other controls
> if the behavior is useful and increases compatibility.  This (bare
> G28) is definitely one of those cases.
> 
> Chris
> 
> -------------------------------------------------------------------------
> This SF.net email is sponsored by: Splunk Inc.
> Still grepping through log files to find problems?  Stop.
> Now Search log events and configuration files using AJAX and a browser.
> Download your FREE copy of Splunk now >>  http://get.splunk.com/
> _______________________________________________
> Emc-users mailing list
> [email protected]
> https://lists.sourceforge.net/lists/listinfo/emc-users
> 


-------------------------------------------------------------------------