Dave Keeton wrote:

>Hi Ray,
>
>         Glad to be here. Thank you for the fast reply.
>
>         I can get classic ladder to come up in demo_step_cl and 
>demo_sim_cl. I guess my question is more about the configuration files for 
>Motenc card. When I look at the moten_io file it reads:
>
># Just uncomment the following line if you want a Software PLC
>#loadusr -w classicladder --nogui ../configs/common/bridgeport.clp
>
>So I edit it to read:
>
># Just uncomment the following line if you want a Software PLC
>loadusr -w classicladder --nogui ../configs/common/bridgeport.clp
>  
>
Hmmm.

Well, it looks like that comment was added way back in the second 
version of the motenc_io.hal file, in December of 2005.  Unfortunately, 
the referenced bridgeport.clp isn't in CVS, and as far as I can tell, it 
never has been.

I'm not sure if Pete V. ever checked it in anywhere, or if he still has it.

In any case, you probably don't want that exact ladder anyway.  If you 
just want to mess around with it, you should be able to copy the .clp 
file from the demo_step_cl directory as a starting point, and change the 
ladder-related lines to read like the ones in the demo_step_cl hal file.

- Steve
[snip]


-------------------------------------------------------------------------