> Is there a simple "get round" for now?

So far I have seen only a couple, incomplete, answers from you.
I still don't know if you use probe_parport in your configs, or if you 
actually need to do that.
Taking that out from the config would probably make your error go away.

> I'm also battling with, it seems, a long outstanding ubuntu trait of not
> shutting down properly :(

you mean after it finished shutting down, it says powering down (or 
something similar) instead of turning itself off?
In that case it's normal and expected. We disabled some things from the 
kernel (ACPI, and other power management related things) which now prevent a 
complete power down. Otoh those interfere with the RealTime system, so I 
think it's more convenient to have to push the switch on shutdown, instead 
of having lost steps during machining :)

> EMC has come a long way since last time I tried it, particularly with
> stepconf making setup easier for non linux users, but there are still a
> few missing features and reliability issues that worry me :(

Well, we could address them, if you can word them.

Regards,
Alex


-------------------------------------------------------------------------