On Tue, Mar 8, 2011 at 4:03 PM, Kirk Wallace <kwall...@wallacecompany.com>wrote:

> On Tue, 2011-03-08 at 15:35 -0600, Igor Chudov wrote:
> ... snip
> > You can only have equal voltages l1-l3, l2-l3, l1-l2, at 120 degree phase
> > angles.
>
> With 0, 90, 180, if the L3 peak to peak is higher than L1-L2, then the
> L1-L3 and L2-L3 could be made to equal L1-L2. I seem to recall that the
> converter capacitor size adjusts this, but the phase angle spacing will
> still be the same.
> --


Capacitors do adjust phase angle.