On Tue, Mar 8, 2011 at 4:03 PM, Kirk Wallace <kwall...@wallacecompany.com>wrote:
> On Tue, 2011-03-08 at 15:35 -0600, Igor Chudov wrote: > ... snip > > You can only have equal voltages l1-l3, l2-l3, l1-l2, at 120 degree phase > > angles. > > With 0, 90, 180, if the L3 peak to peak is higher than L1-L2, then the > L1-L3 and L2-L3 could be made to equal L1-L2. I seem to recall that the > converter capacitor size adjusts this, but the phase angle spacing will > still be the same. > -- Capacitors do adjust phase angle. i ------------------------------------------------------------------------------ What You Don't Know About Data Connectivity CAN Hurt You This paper provides an overview of data connectivity, details its effect on application quality, and explores various alternative solutions. http://p.sf.net/sfu/progress-d2d _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users