I'm testing a 1mm/min move, repeating {g1 x1.0, pause, g0 x0, pause}
kind of tests. With > setp hm2_5i25.0.stepgen.01.steplen 1500 > setp hm2_5i25.0.stepgen.01.stepspace 2500 > setp hm2_5i25.0.stepgen.01.dirhold 2000 > setp hm2_5i25.0.stepgen.01.dirsetup 2000 changed to 6,000 for each parameter, the system seems stable at 1mm/min. (test still going) Then to try an hour long test with a feed of 0.5 or 0.25, and see if there's lost steps when creeping along. And, I'll have to read through what these parameters actually do... JohnS. ------------------------------------------------------------------------------ Get your SQL database under version control now! Version control is standard for application code, but databases havent caught up. So what steps can you take to put your SQL databases under version control? Why should you start doing it? Read more to find out. http://pubads.g.doubleclick.net/gampad/clk?id=49501711&iu=/4140/ostg.clktrk _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users