On 28 May 2016 at 05:52, Danny Miller <dan...@austin.rr.com> wrote:
> No, no LinuxCNC axis moves.  If I expand FERROR way out, the display
> says it's moving like 0.5" before erroring- but the physical axis never
> moves.

One way to check if you have Hostmot2 communication would be to try to
light the LEDs on the 7i92 board.
halcmd setp hm2_7i92.0.CR01 1

This situation sounds a lot like what you might get if the hm2_7i92
read/write functions were not added to a thread.

-- 
atp
"A motorcycle is a bicycle with a pandemonium attachment and is
designed for the especial use of mechanical geniuses, daredevils and
lunatics."
— George Fitch, Atlanta Constitution Newspaper, 1916

------------------------------------------------------------------------------