On 13.09.16 06:51, Gene Heskett wrote: > The ideal cable would be a star-quad that Clark Wire in windy carried 20 > years ago, it was 18 gauge in a mylar film covered in 68% braided > shield, very limp stuff. But Susan is not importing the heavier gauges > anymore, and its a piece of her 24 gauge thats heating while driving the > x motor on the little monster. So as I revive the little monster, some > of that grey stuff will be used to replace it. But that drag chain has > a much smaller turn around, abusing that cable, so that will fail > faster. How fast remains TBD.
Will TLM remain in use, or be decommissioned once the Sheldon flies? If the former, perhaps parallel two runs of the flexible stuff¹; if the latter, then either way works? Erik ¹ Two runs might lead to 1/9 of the heating, through tripling of the power conductors, since there's no call to parallel the signal conductors. ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users