On Mar 17, 2018 6:50 PM, "andy pugh" <bodge...@gmail.com> wrote:
On 17 March 2018 at 22:44, Mark Wendt <wendt.m...@gmail.com> wrote: > Maybe I'm missing something here. You suggested in your previous email to > edit the zpos-cmd line to: > > net zpos-cmd stepgen.2.position-cmd > > If I do that then there's no linking offset.0.out to stepgen.2.position-cmd > in either of the hal files. There is if both pins are connected to the zpos-cmd signal. ie, this : net zpos-cmd stepgen.2.position-cmd offset.0.out Is functionally identical to: net zpos-cmd stepgen.2.position-cmd net zpos-cmd offset.0.out Even if the two separate lines are in different HAL files. Okay now I understand. Makes sense to me now that you explained what confused me. Thanks!!!!!! Mark ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users