On Mar 17, 2018 6:50 PM, "andy pugh" <bodge...@gmail.com> wrote:

On 17 March 2018 at 22:44, Mark Wendt <wendt.m...@gmail.com> wrote:

> Maybe I'm missing something here. You suggested in your previous email to
> edit the zpos-cmd line to:
>
> net zpos-cmd stepgen.2.position-cmd
>
> If I do that then there's no linking offset.0.out to
stepgen.2.position-cmd
> in either of the hal files.

There is if both pins are connected to the zpos-cmd signal.

ie, this :

net zpos-cmd stepgen.2.position-cmd offset.0.out

Is functionally identical to:

net zpos-cmd stepgen.2.position-cmd
net zpos-cmd offset.0.out

Even if the two separate lines are in different HAL files.


Okay now I understand. Makes sense to me now that you explained what
confused me. Thanks!!!!!!

Mark
------------------------------------------------------------------------------
Check out the vibrant tech community on one of the world's most
engaging tech sites, Slashdot.org! http://sdm.link/slashdot
_______________________________________________
Emc-users mailing list
Emc-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to