Alon Bar-Lev has posted comments on this change.

Change subject: tools: support snmp trap as a notification method.
......................................................................


Patch Set 15:

(4 comments)

minor notes.

http://gerrit.ovirt.org/#/c/22909/15/backend/manager/tools/src/main/java/org/ovirt/engine/core/notifier/sender/snmp/SNMPEventSender.java
File 
backend/manager/tools/src/main/java/org/ovirt/engine/core/notifier/sender/snmp/SNMPEventSender.java:

Line 75:                     new OID(trapOID).append(3),
Line 76:                     new 
OctetString(auditLogEvent.getLogTime().toString())));
Line 77:             CommunityTarget target = new CommunityTarget();
Line 78:             final String[] split = 
AuditLogEventSubscriber.getMethodAddress().split(":");
Line 79:             target.setAddress(new UdpAddress(split[0] + "/" + 
(split.length > 1 ? split[1] : 162)));
why is the loop of sending to multiple managers is not here?
Line 80:             target.setCommunity(new 
OctetString(prop.getProperty(NotificationProperties.SNMP_COMMUNITY)));
Line 81:             target.setVersion(SnmpConstants.version2c);
Line 82:             target.setRetries(2);
Line 83:             target.setTimeout(5000);


Line 79:             target.setAddress(new UdpAddress(split[0] + "/" + 
(split.length > 1 ? split[1] : 162)));
Line 80:             target.setCommunity(new 
OctetString(prop.getProperty(NotificationProperties.SNMP_COMMUNITY)));
Line 81:             target.setVersion(SnmpConstants.version2c);
Line 82:             target.setRetries(2);
Line 83:             target.setTimeout(5000);
I still do not understand these settings regarding udp.
Line 84:             snmp.send(v2pdu, target);
Line 85:             final EventSenderResult eventSenderResult = new 
EventSenderResult();
Line 86:             eventSenderResult.setSent(true);
Line 87:             return eventSenderResult;


http://gerrit.ovirt.org/#/c/22909/15/packaging/services/ovirt-engine-notifier/ovirt-engine-notifier.conf.in
File packaging/services/ovirt-engine-notifier/ovirt-engine-notifier.conf.in:

Line 124: # SNMP_FILTER_MODE=exclude|include
Line 125: SNMP_FILTER_MODE=exclude
Line 126: 
Line 127: # A whitespace separated events list.
Line 128: SNMP_FILTER=""
no need for ""
Line 129: 
Line 130: # Notice by default all events are sent (exclude "").
Line 131: 
Line 132: #----------------------------------#


Line 126: 
Line 127: # A whitespace separated events list.
Line 128: SNMP_FILTER=""
Line 129: 
Line 130: # Notice by default all events are sent (exclude "").
remove this comment?
Line 131: 
Line 132: #----------------------------------#
Line 133: # Engine Monitoring Configuration: #
Line 134: #----------------------------------#


-- 
To view, visit http://gerrit.ovirt.org/22909
To unsubscribe, visit http://gerrit.ovirt.org/settings

Gerrit-MessageType: comment
Gerrit-Change-Id: I0cd22d022ae535f45e046b09a2cbfadd837b465c
Gerrit-PatchSet: 15
Gerrit-Project: ovirt-engine
Gerrit-Branch: master
Gerrit-Owner: mooli tayer <[email protected]>
Gerrit-Reviewer: Alon Bar-Lev <[email protected]>
Gerrit-Reviewer: Doron Fediuck <[email protected]>
Gerrit-Reviewer: Eli Mesika <[email protected]>
Gerrit-Reviewer: Liran Zelkha <[email protected]>
Gerrit-Reviewer: Martin PeÅ™ina <[email protected]>
Gerrit-Reviewer: mooli tayer <[email protected]>
Gerrit-Reviewer: oVirt Jenkins CI Server
Gerrit-HasComments: Yes
_______________________________________________
Engine-patches mailing list
[email protected]
http://lists.ovirt.org/mailman/listinfo/engine-patches

Reply via email to