I've seen dust get on the back plane and cause this. If you pull it out and blow everything out and then let the code download from the good blade sometimes it will come back otherwise give GTAC a call as you will likely need a replacement blade.
Thanks Bruce Hopkins 770-528-4574 Director Information Systems Chattahoochee Technical College http://www.chattcollege.com Any fool can make things bigger, more complex, and more violent. It takes a touch of genius - and a lot of courage - to move in the opposite direction. Albert Einstein -----Original Message----- From: Javed Khan [mailto:[EMAIL PROTECTED] Sent: Wednesday, November 12, 2008 10:34 AM To: Enterasys Customer Mailing List Subject: [enterasys] 7G4270-12 module shows RED CPU LED Dear All, N7 chassis is populated with one 7G4270-12 MTRG fiber module & one 7H4382-48 module. Now the 7G4270-12 MTRG fiber module is showing RED CPU LED. Pls let know the possible causes for the same & how to troubleshoot. Regards, Javed Khan 91-9920111017 --- To unsubscribe from enterasys, send email to [EMAIL PROTECTED] with the body: unsubscribe enterasys [EMAIL PROTECTED] --- To unsubscribe from enterasys, send email to [EMAIL PROTECTED] with the body: unsubscribe enterasys [EMAIL PROTECTED]