What does the console port say when you restart the blade? Could be POST failure (Power On Self Test). Does the blade work on its own when no other blades are inserted in the chassis? I have seen this if modules have incompatible DIP-switch settings, that's why I suggest trying the blade by itself. Does the neighbouring blade's console say anything when you insert the 'faulty' blade?
I think that Enterasys will need the console output when you RMA the device. Regards Stephen Rikshospital Oslo. (In compliance with the Security Policy of Rikshospitalet HF , the content of this message (including any attachments) is of a non-sensitive nature) -> -----Original Message----- -> From: Bruce Hopkins [mailto:[EMAIL PROTECTED] -> Sent: Wednesday, November 12, 2008 8:55 PM -> To: Enterasys Customer Mailing List -> Subject: RE: [enterasys] 7G4270-12 module shows RED CPU LED -> -> I've seen dust get on the back plane and cause this. If you -> pull it out and blow everything out and then let the code -> download from the good blade sometimes it will come back -> otherwise give GTAC a call as you will likely need a -> replacement blade. -> -> -> -> Thanks -> Bruce Hopkins -> 770-528-4574 -> Director Information Systems -> Chattahoochee Technical College -> http://www.chattcollege.com -> -> Any fool can make things bigger, more complex, and more -> violent. It takes a touch of genius - and a lot of courage - -> to move in the opposite direction. -> Albert Einstein -> -> -----Original Message----- -> From: Javed Khan [mailto:[EMAIL PROTECTED] -> Sent: Wednesday, November 12, 2008 10:34 AM -> To: Enterasys Customer Mailing List -> Subject: [enterasys] 7G4270-12 module shows RED CPU LED -> -> Dear All, -> -> N7 chassis is populated with one 7G4270-12 MTRG fiber module & one -> 7H4382-48 module. -> -> Now the 7G4270-12 MTRG fiber module is showing RED CPU LED. -> Pls let know the possible causes for the same & how to troubleshoot. -> -> Regards, -> -> Javed Khan -> 91-9920111017 -> -> --- -> To unsubscribe from enterasys, send email to -> [EMAIL PROTECTED] with the body: unsubscribe enterasys -> [EMAIL PROTECTED] -> -> --- -> To unsubscribe from enterasys, send email to -> [EMAIL PROTECTED] with the body: unsubscribe enterasys -> [EMAIL PROTECTED] -> --- To unsubscribe from enterasys, send email to [EMAIL PROTECTED] with the body: unsubscribe enterasys [EMAIL PROTECTED]