木村と申します。

At 09:54 07/02/08, you wrote:
>もしかすると、Chip は OEM ですから問題無いでしょうけど、BIOS で
>返す自分の Device のモデルとかの関係上
>
>Dell PERC 5ei
>
>が対応(検証)されないと辛いのかもしれません。

  PowerEdge2950 でなくて PowerEdge1950 の Dell PERC5/i の例ですが、
FreeBSD6.2R で動作しています。MegaRAID 系ですがドライバは amr ではなく
mfi です。

% dmesg | grep ^mfi
mfi0: <Dell PERC 5/i> mem 0xd80f0000-0xd80fffff,0xfc4e0000-0xfc4fffff irq 78 at 
device 14.0 on pci2
mfi0: 1546 (224221533s/0x0020/0) - Shutdown command received from host
mfi0: 1547 (4278190080s/0x0020/0) - PCI 0x041028 0x0415 0x041028 0x041f03: 
Firmware initialization started (PCI ID 0015/1028/1f03/1028)
mfi0: 1548 (4278190080s/0x0020/0) - Type 18: Firmware version 1.00.01-0088
mfi0: 1549 (4278190090s/0x0008/0) - Battery Present
mfi0: 1550 (4278190107s/0x0004/0) - PD 08(e1/s255) event: Enclosure (SES) 
discovered on PD 08(e1/s255)
mfi0: 1551 (4278190108s/0x0002/0) - PD 08(e1/s255) event: Inserted: PD 
08(e1/s255)
mfi0: 1552 (4278190108s/0x0002/0) - Type 29: Inserted: PD 08(e1/s255) Info: 
enclPd=08, scsiType=d, portMap=00, sasAddr=500180b03a123d00,0000000000000000
mfi0: 1553 (4278190108s/0x0002/0) - PD 00(e1/s0) event: Inserted: PD 00(e1/s0)
mfi0: 1554 (4278190108s/0x0002/0) - Type 29: Inserted: PD 00(e1/s0) Info: 
enclPd=08, scsiType=0, portMap=01, sasAddr=1221000000000000,0000000000000000
mfi0: 1555 (4278190108s/0x0002/0) - PD 01(e1/s1) event: Inserted: PD 01(e1/s1)
mfi0: 1556 (4278190108s/0x0002/0) - Type 29: Inserted: PD 01(e1/s1) Info: 
enclPd=08, scsiType=0, portMap=02, sasAddr=1221000001000000,0000000000000000
mfi0: 1557 (224222092s/0x0020/0) - Adapter ticks 224222092 elapsed 28s: Time 
established as 02/08/07  3:54:52; (28 seconds since power on)
mfi0: 1558 (224222149s/0x0008/0) - Battery temperature is normal
mfi0: 1559 (224222149s/0x0008/0) - Current capacity of the battery is above 
threshold
mfid0: <MFI Logical Disk> on mfi0
mfid0: 237824MB (487063552 sectors) RAID volume 'Virtual Disk 0' is optimal

--- 

 木村 孝雄
 e-mail: [EMAIL PROTECTED],[EMAIL PROTECTED],[EMAIL PROTECTED] 

メールによる返信