> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of Laine, Rogers
>
> John,
>
> It may have to do with the printer selection.
>
> On the system console enter F vs. task name,DISPLAY,printer
> name,STATUS
>
> It will reflect the following messages.
> The VPS981R message shows that printer W3105 is IDLE with a
> Class Selection of A and WRITER ID of W3105.
>
> Then see what JES has for this print job.
>
> I'm not sure if a PDF document has any thing to do with job selection.
>
> Rogers
>
>
>
> F VPS,DISPLAY,W3105,STATUS
> VPS920R W3105 DISPLAY COMMAND ACKNOWLEDGED
> VPS981R W3105 IDLE C=A W=W3105
F VPS,DISPLAY,EVLHP90F,STATUS
VPS920R EVLHP90F DISPLAY COMMAND ACKNOWLEDGED
VPS981R EVLHP90F IDLE C=T D=VPSEVAL2 F=ABCD W=PDF
And on the SDSF Output queue display:
JOBNAME JNUM PRTY C FORM FCB DEST DEVICE TOT-REC JP UCS
FLASH BURST WTR ODISP
WHLTRNP4 14554 157 T ABCD **** VPSEVAL2 90 1 ****
**** NO PDF WRITE
-jc-
----------------------------------------------------------------------