Eileen Barkow wrote:

<snip>

i was under the impression that the entire dump was copied into
Abendaid's own datasets and viewed from there, but from what you are
saying, that is not the case - the actual dump is being used for
viewing. Now it makes sense.

</snip>

When you use the post dump exit the SVC dump is indeed copied from the
SYS1.DUMPxx data set to a user specified data set and analyzed/viewed
from there.  I was pointing out the reasons why Abend-AID for CICS
refuses to import a dump _directly_ from a SYS1.DUMPxx data set.



Mike Conmackie
Software Developer
Compuware Corporation
1 Campus Martius
Detroit, MI   48226