On Fri, 28 Mar 2008 16:02:28 +0000, Jacky Bright <[EMAIL PROTECTED]> wrote:

>Liz,
>
>Thanks but this is like IPLing the system itself which involves outage which
>many not be possible in our system So I was just looking for alternatives...
>
>

There is really not much harm in doing $PJES2,ABEND and replying "END" to 
not take a dump and restarting it.   It will interrupt printing, NJE and remotes
if you have them.   So other than draining printers you usually can just
restart your lines / NJE connections after a JES2 bounce.   Much less 
disruptive than an IPL.

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - ZFUS G-ITO
mailto:[EMAIL PROTECTED]
z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html