All of the issues will be indicated in the SMPOUT DD. Anything that
shows "system utility failure" (or something similar) will need to be
fixed. About the only thing that should remain after the last run (once
all issues have been fixed) are unresolved error holds.

<<snip>>
> <snip>
>    My next question is: Since I did get 835 PTFs on (all that didn't
> involve NUCLEUS), can I go forward, or should I start over one more
> time? Or restore from back up to the pre APPLY state and run again. Or
> SMP/E restore?
> </snip>
> 
> Just rerun the apply, fixing problems until a clean run is achieved.
> Each run will remember what the previous runs accomplished, and only
> attempt to apply the stuff previously in error.

   Yahbut, I did run the 835 successful PTFs with the 1.7 system against
the 1.9 target? Is NUCLEUS (which failed) my only worry?
<</snip>>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html