Changes were only performed from the plex without the PDSE in linklist,
all I want is for the other plex to be able to pick up the changes.
Easy to do with a PDS, why so difficult with a PDSE? 

-----Original Message-----
Kevin Mckenzie

You could try this (haven't tested it, but I think it should work,
assuming you haven't made any changes to the PDSE on the plex that has
it in linklist):  remove PDSE from LLA and linklist.  On the system you
made the change from, copy the contents of the PDSE into a new PDSE,
accessible from both systems.  Add the new PDSE to LLA and linklist on
the original plex.  If you've made changes from both plexes, I don't
think there's any good way to recover.

Kevin McKenzie


Ken Porowski <

I have a PDSE in linklist on one plex and not referenced on another
plex. 
The PDSE was updated from the plex not using it (all shared dasd).
An LLA refresh was performed on one system of the using plex.
Task which uses the lib gets the 'old' members.
I do not run restartable SMSPDSE1.

Attempting a member list gets an IEC036I 002-A4.

Any easy way to fix this?

Yes, I know I wasn't supposed to do this but I forgot it was a PDSE.

TIA

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to