From: Porowski, Ken 

PLEX-1 has PDSE in linklist
PLEX-2 does not have PDSE in linklist
IEBCOPY with DISP=SHR run on PLEX-1 and got  213-70 IEBCOPY with
DISP=SHR run on PLEX-2 ran clean LLA refresh on PLEX-1 Bounced task
using PDSE (via linklist) on PLEX-1 (one system only, all others will
not reference the PDSE) Task using PDSE does not get new members.

Currently 'fixed' by allocating a new PDSE and loading it with the
updated members.
Allocated a new linklist set replacing the 'bad' PDSE with the new one.
Activated the new linklist set on all members of PLEX-1 SETPROG
LNKLST,UPDATE,JOB=*

On a different member of PLEX-1 I tried (before the 'fix' mentioned
above) P LLA SETPROG LNKLST,UNALLOCATE S LLA,SUB=MSTR SETPROG
LNKLST,ALLOCATE This was definitely the wrong move, LLA would not
initialize because of the 'broken' PDSE Linklist unable to find modules
Abends all over the place.
ABEND0F4 RSN24
ABEND023 RSN17
ABEND023 RSN201
212-00 on DUMPSRV
Do not try this at home!

Fixed for now but I wonder what is the 'proper' way of handling a PDSE
in linklist?

----------------------------------------------------------------------