From: Porowski, Ken PLEX-1 has PDSE in linklist PLEX-2 does not have PDSE in linklist IEBCOPY with DISP=SHR run on PLEX-1 and got 213-70 IEBCOPY with DISP=SHR run on PLEX-2 ran clean LLA refresh on PLEX-1 Bounced task using PDSE (via linklist) on PLEX-1 (one system only, all others will not reference the PDSE) Task using PDSE does not get new members.
Currently 'fixed' by allocating a new PDSE and loading it with the updated members. Allocated a new linklist set replacing the 'bad' PDSE with the new one. Activated the new linklist set on all members of PLEX-1 SETPROG LNKLST,UPDATE,JOB=* On a different member of PLEX-1 I tried (before the 'fix' mentioned above) P LLA SETPROG LNKLST,UNALLOCATE S LLA,SUB=MSTR SETPROG LNKLST,ALLOCATE This was definitely the wrong move, LLA would not initialize because of the 'broken' PDSE Linklist unable to find modules Abends all over the place. ABEND0F4 RSN24 ABEND023 RSN17 ABEND023 RSN201 212-00 on DUMPSRV Do not try this at home! Fixed for now but I wonder what is the 'proper' way of handling a PDSE in linklist? ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html