Not DASD datasets, but FDR backup and migration tapes cannot be copied with 
IEBGENER (they appear to be PS tape datasets).  The BMC manuals explicitly say 
that.


"Confidentially doc, I am the wabbit."

Bugs Bunny

Sent from Proton Mail for Android.

-------- Original Message --------
On Friday, 12/26/25 at 10:36 [email protected] <[email protected]> 
wrote:
>Special - examples: DFSMShsm journal, RACF db, SMF SYS1.MANx, IODF, etc.
>Each of them *looks like* PS or VSAM, but there are additional rules and
>constraints which have to be followed.

In my opinion, for what little it might be worth, it is unfortunate that there 
is not a standard term or notation for such "special" datasets in the general 
z/OS documentation. Among other things, these are datasets where the normal 
z/OS utilities might have unwanted results, etc, etc. Some of these have been 
around almost since the beginning (OS/360 days) and the numbers have grown 
(unfortunately).

They can result in unexpected stumbles for newer systems programmers (or 
"administrators" in the more modern terminology).