Yes, UNLOADED IRRUT400 worked for me and now RACF is at AIM stage 3. As > I mentioned earlier, we have we have z/OS 1.13 and z/OS 2.1 system in > sysplex. So, As per document upto z/OS 1.13, we can use BPX.DEFAULT.USER > and then on z/OS 2.1, we will have to use BPX.UNIQUE.USER . > > But when I followed below link to setup BPX.UNIQUE.USER . > > > http://pic.dhe.ibm.com/infocenter/zos/v1r12/index.jsp?topic=%2Fcom.ibm.zos.r12.icha700%2Fautosvc.htm > > still I am getting omvs segment issue while working with any user, who is > trying to get into omvs segment. > > 1) See your system programmer to ensure that your RACF database is > enabled for AIM stage 3 > 2) Define the SHARED.IDS profile, if not already defined, in the UNIXPRIV > class and activate and RACLIST the UNIXPRIV class > 3) Define the BPX.NEXT.USER profile in the FACILITY class, if not already > defined. For instructions, > 4) Define a user profile to use as a model profile from which RACF can > extract OMVS segment information > > ADDUSER BPXMODEL NAME('OMVS model user profile') > OMVS(NOUID HOME('/tmp')) > NOPASSWORD RESTRICTED > > 5) Define the BPX.UNIQUE.USER profile in the FACILITY class and specify the > name of the model profile in the APPLDATA field. > > RDEFINE FACILITY BPX.UNIQUE.USER APPLDATA('BPXMODEL') > > 6) If the FACILITY class is RACLISTed, activate your new FACILITY profiles by > refreshing the FACILITY class. > > SETROPTS RACLIST(FACILITY) REFRESH > > > Please suggest. > > > On Fri, Feb 14, 2014 at 10:48 PM, Russell D Hardgrove <[email protected] > > wrote: > >> Has to have been UT400. >> UT200 never locks it. >> DBU00 can LOCK it but it UNLOCKS it at EOJ. >> UT400 needs an explicit UNLOCK. >> >> >> . >> -------------------------------------------------- >> Russ Hardgrove / RACF Lvl2 >> IBM - z/OS Software Service >> Dept. EC8A (working remotely) >> Poughkeepsie, NY 12601 >> [email protected] 845-435-3279 (a voicemail box only) >> -------------------------------------------------- >> "RACF: Guilty, until proven innocent !!" RdH 2004 >> "RACF, praesumitur malus donec probetur bonus" RdH MMX >> << Continually proving this (innocence) is not just a JOB, it's an >> -ADVENTURE- :-b .. >> >> ... >> >> >> >> From: Lennie J Dymoke-Bradshaw <[email protected]> >> To: [email protected], >> Date: 02/14/2014 12:14 PM >> Subject: Re: RACF AIM Stage 3 Issue >> Sent by: RACF Discussion List <[email protected]> >> >> >> >> Is it possible you have run IRRUT400 or IRRUT200 against the database and >> left it in locked status? >> >> You can unlock it again using the UNLOCKINPUT parameter on IRRUT400. >> >> http://pic.dhe.ibm.com/infocenter/zos/v1r13/index.jsp?topic=%2Fcom.ibm.zos.r13.icha200%2Fichza2c0118.htm >> >> >> See Example 7. >> >> Lennie Dymoke-Bradshaw MBCS CITP >> Accredited Senior I/T Specialist, System z, Security and Cryptography, IBM >> Software Group >> Mail: Lennie J Dymoke-Bradshaw/UK/IBM@IBMGB or >> [email protected] >> There are two types of people in the world; those who have been hacked, >> and those who will be hacked. >> >> >> >> >> From: venkat kulkarni <[email protected]> >> To: [email protected], >> Date: 14/02/2014 17:00 >> Subject: RACF AIM Stage 3 Issue >> Sent by: RACF Discussion List <[email protected]> >> >> >> >> Hello, >> I am trying to setup BPX.UNIQUE.USER. >> >> >> While upgrading RACF template, I am getting below issues. >> >> //RACFAIM JOB (657),'VENKAT',CLASS=A,MSGCLASS=X,NOTIFY=&SYSUID >> //STEP EXEC PGM=IRRIRA00,PARM=STAGE(3) >> //SYSPRINT DD SYSOUT=* >> >> >> >> IRR66017I The system is currently operating in stage 2. >> IRR66016I Unexpected RACF manager return code deleting entry G0 in class >> UNIXMAAP. Return code 80. Reason code 0. >> >> >> 50 (80) An attempt was made to update one of the following (by a request >> other than ALTERI): >> The RACF database that has been locked by a RACF utility >> The RACF database from a system that is in read-only mode (in a RACF >> sysplex data sharing environment) >> >> In My RACF TABLE >> >> In my RACF table, we using >> >> ICHRDSNT CSECT >> DC AL1(1) >> DC CL44'SYS1.V2R1.RACFP' >> DC CL44'SYS1.V2R1.RACFB' >> DC AL1(255) >> DC X'80' >> END >> >> >> >> Can anybody help. >> >> >> >> Unless stated otherwise above: >> IBM United Kingdom Limited - Registered in England and Wales with number >> 741598. >> Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU >> > >
---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
