We use &SYSR1 through &SYSR5 to have a 5 pack resvol set (note these include OMVS related HFS/ZFS - hence the number/sizes) and have no issues. Biggest problem I have is folks inadvertently recataloging the datasets from their indirect values while doing maintenance so we locked down the Master Cat such that even the Sysprogs have restrictions on what they can change.
Jerry Whitteridge Manager Mainframe Systems & Storage Albertsons - Safeway Inc. 925 738 9443 Corporate Tieline - 89443 If you feel in control you just aren't going fast enough. -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Lucas Rosalen Sent: Thursday, April 21, 2016 2:14 AM To: [email protected] Subject: EXTERNAL: Re: Respack Volume Size Challenge As far as I have seen, it's quite simple: create a &SYSR2 symbol (using &SYSR1 and changing last char from 1 to 2, for example) and update MCAT accordingly. Once I've worked for a client that had 3-volumes respack. It indeed worked. We used to keep datasets like LINKLIB, MACLIB, NUCLEUS, etc in 1st volumes though... ------------------------------------------------------------------------------------------------------------------------------- *Lucas Rosalen* Emails: [email protected] / *[email protected] <[email protected]>* LinkedIn: http://br.linkedin.com/in/lrosalen Phone: +48 (71) 792 809 198 2016-04-21 10:45 GMT+02:00 Jake Anderson <[email protected]>: > Hello, > > From the z/OS 2.1, I have started using Mod-27 as the Load address(Respack) > for IPLing the z/OS 2.1 LPAR. I am curious how the other Shops are managing > when they do not options of using Mod-27 and they have to survive with > Mod-9. I believe the Extended Indirect cataloging is one Options. > > What kind of challenges are there when the Respack is divided into two > Volumes ? > > Jake > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ________________________________ Warning: All e-mail sent to this address will be received by the corporate e-mail system, and is subject to archival and review by someone other than the recipient. This e-mail may contain proprietary information and is intended only for the use of the intended recipient(s). If the reader of this message is not the intended recipient(s), you are notified that you have received this message in error and that any review, dissemination, distribution or copying of this message is strictly prohibited. If you have received this message in error, please notify the sender immediately. ________________________________ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN