Here's what OAM is telling me
CBR0001I OAM initialization starting.                                       
CBR0119I Entry default data class for library WVCHAS not available.         
CBR0119I Entry default data class for library WVFLAT not available.         
CBR3006I Library WVCHAS with Library ID D7720 unknown in I/O configuration. 
CBR3002E Library WVCHAS no longer usable.                                   
CBR3006I Library WVFLAT with Library ID D7740 unknown in I/O configuration. 
CBR3002E Library WVFLAT no longer usable.                                   
CBR3006I Library WV7700 with Library ID C0001 unknown in I/O configuration. 
CBR3002E Library WV7700 no longer usable.                                   
CBR3911I There is no online and operational tape library.   

There are two ficon connections and they are currently online.  I have tried 
varying them off and back on... multiple times.

Here's  output from D M=CHP(42):
IEE174I 20.26.00 DISPLAY M 014                                  
 CHPID 42:  TYPE=1D, DESC=FICON INCOMPLETE, ONLINE               
 DEVICE STATUS FOR CHANNEL PATH 42                               
      0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F             
 0020 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0021 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0022 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0023 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0024 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0025 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0026 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0027 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0028 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 0029 +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 002A +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 002B +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 002C +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 002D +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@            
 002E +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@ +@       
SWITCH DEVICE NUMBER = NONE                                              
ATTACHED ND = NOT KNOWN                                                  
PHYSICAL CHANNEL ID = 0118                                               
************************ SYMBOL EXPLANATIONS ************************    
+ ONLINE    @ PATH NOT VALIDATED   - OFFLINE    . DOES NOT EXIST         
* PHYSICALLY ONLINE   $ PATH NOT OPERATIONAL                                  
                

Anne D. Crabtree
System Programmer 
WV Office of Technology Data Center
1900 Kanawha Blvd East
Bldg 6, Room B-110
Charleston, WV  25305
(304)957-8292 
(304)558-1441 fax
Work Hours: 6AM-2PM EST

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Lizette Koehler
Sent: Sunday, December 04, 2016 8:15 PM
To: [email protected]
Subject: Re: 3957-VEA TS7720 power outage

I was wondering when you bring it online, what error messages do you see?

There should be some IOS or IEA type messages for the VTS to say whether or not 
z/OS is "seeing" it or not.

I do not know about the TS7720 to provide some other options.

But when our OEM VTS has issues, there is a log on the OEM equipment I can look 
at and the SYSLOG usually has some messages as well.

Sometimes Ficon gets confused.  Varying offline/online sometimes help - but I 
am not sure if UCBs or the whole Library needs to come offline/online for your 
situation.

Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] 
> On Behalf Of Crabtree, Anne D
> Sent: Sunday, December 04, 2016 5:58 PM
> To: [email protected]
> Subject: 3957-VEA TS7720 power outage
> 
> Looking for anyone who know something about a TS7720 to help me!  This 
> machine Is in a hybrid configuration and we had a planned power outage this 
> morning.
> I placed the cluster in service mode and then did a cluster shutdown.  
> When power was restored, our zBC12 cannot talk to the VTL!  We've 
> tried everything, Hoping someone out there can help.  Again, this is a 
> 3957-VEA TS7720 (1.7 release).Our mainframe is a zBC12 and is 
> physically connected via ficon to this VTL.  If this is not enough 
> information, let me know... I'll do my best to describe the situation.  
> We do not have a contract with IBM in place at this time and having 
> been working with hardware support and software support trying to receive 
> help.  In the meantime, any input would be appreciated!
> 
> Anne D. Crabtree
> System Programmer
> WV Office of Technology Data Center
> 1900 Kanawha Blvd East
> Bldg 6, Room B-110
> Charleston, WV  25305
> (304)957-8292
> (304)558-1441 fax
> Work Hours: 6AM-2PM EST
> 

----------------------------------------------------------------------