As I understand it, Scott's COBOL programs are all 31-bit addressing. It is the 
Assembler programs which are not.

If any of the COBOL programs happened to be located outside the 24-bit range of 
addresses, the thing would stop working, or certainly not work as expected, as 
return-address and the address of the save-area would be subjected to a bit of 
stripping.

This could easily be tested, as even with Enterprise COBOL V3.1, a single 16MB 
field could be defined, which would then ensure that any return-address or 
save-area would be outside the 24-bit addressability.

----------------------------------------------------------------------