Can anyone offer advice on how to report on load modules held in a specific
PDS (or PDS(E) - I'm not fussy) being loaded by specific batch jobs, please?
I've tried looking at SMF type 14 - but that only shows the load library
being opened - nothing about modules.
I've tried using RACF event type 2 data generated as a result of specifying
ralter PROGRAM ** addmem('<library name>'//NOPADCHK)
but again I see only the library being accessed - nothing about the modules
involved
I've tried using GTF with a SLIP trap for SVC8 and SVC122 (yes - some of
the 'modules' concerned are DLL's), but I still don't see anything like the
amount of accesses I'm expecting.
I'm rapidly running out of ideas, here.
Hopefully
Sean
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN