Install the latest and greatest, and then just hope the problem is fixed? I think *NOT*
-----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Brian Westerman Sent: Saturday, February 17, 2018 8:22 PM To: [email protected] Subject: Re: SMS dataset oddity with COM-Plete No, the volumes are identical (same raid, same channels, etc.) except that the one (that results in an s0C1) is in an SMS pool and the other is not. The data got to the pool because we sent it there via a dfdss batch job to move all of the development datasets to a "new" 48 volume development pool instead of just a few development 3390-3's. The only difference between them via 3.4 seems to be that one has a storage class and management class (no dataclass) and the other doesn't (because it's not on an SMS volume. The vendor (SAG) is no help at all, as they feel that since Com-Plete 6.8.1 works fine with it on either volume that we should just migrate to the new version now. Unfortunately, that's not a viable option because they have to upgrade Natural and Adabas first and that project has just started (that's why the Com-Plete cutover is January of 2019). Strangely enough, we have another customer, at the same level of Com-Plete, exactly same PTF level and compile dates on the programs, and they have no problem editing dataset from the SMS volumes. I have compared the sites com-plete (s) and they are not just virtually identical, they are exactly identical. One site though (the site that works) is z/OS 1.8 (in the process of moving to z/OS 2.3), but the other (the one where it fails) is at z/OS 2.2. I have no real doubts that the issue is something within SMS under z/OS 2.2 (or something that changed between 1.8 and 2.2), but the problem is to locate and neutralize it before the site that is currently converting to 2.3 ends up with the same issue. They have no plans to upgrade their Software AG environment (it's slowly disappearing). Brian ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ::DISCLAIMER:: -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN